Skip to main content
mobile

Heritázs

  • Search
  • Collections
Englishen
  • Magyarhu
  • Српскиsr
  • Serbo-Croatiansh
LoginRegister
  • Volume Overview
  • Page
  • Text
  • Metadata
  • Clipping
Preview
srb_000007/0000

Charisma - J_Dyer_G_Verri_and_J_Cupitt_Multispectral

  • Preview
  • Show Metadata
  • Show Permalink
Total Pages
192
Collection
Presentations of MSI conference in Serbia
srb_000007/0166
  • Volume Overview
  • Page
  • Text
  • Metadata
  • Clipping
Page 167 [167]
  • Preview
  • Show Permalink
  • JPG
  • TIFF
  • Prev
  • Next
srb_000007/0166

OCR

cas A NI 7 19) The points are moved by left-clicking and dragging on the label. Move these to indicate a pair of features on the standards which are recognisable in both images. Better accuracy is achieved if these points as far apart as possible. Note that it is not essential to use the standards themselves for the alignment (which may be difficult if, for example, the image is quite dark), as long as these are correctly aligned in both images. Note that the image will update in real time, which may cause a slight response delay in larger images. {3 *F:\ Technical Imaging\ John Cupitt\zip files\bm2\bm-workspaces2.ws - align = =/5)> File Edit View Tookits Help peg input | linear | markup " viscalb . uvicalb | align | specden . falsecolour | KELETT Elle View Help Vo A- match UV-induced visible luminescence to vis x i 2592x3888 32-bit float, 3 bands, XYZ, 115.33 MB, 1x1 pimm (2591, 1050) _0.907281_0.260463_0.620769__ Magnification 1:6 A S| a1 | uvicalib.26 <> Ce ee eA RES adjust A v < D) 1 Figure 3-69 20) To test the accuracy of the alignment, double left-click on the A2 “test_alignment” thumbnail (Figure 3-70). 21) Scroll down to the VIS and UVL images to be calibrated (A3). These can be the same as those in A2 (as shown in the above examples) or different images (as in Figure 3-71). 22) Double left-click on the A3 “reference” thumbnail to bring up the image view window containing the VIS image and two points, A3.apl and A3.ap2. These should be automatically placed in the same locations as for the D1 “reference” VIS image. Zoom in or out of the image as necessary by pressing “+” or “-” (or “i” or “o”) respectively. 23) Move these to indicate a pair of features which are recognisable in both images. Better accuracy is achieved if these points as far apart as possible. Note that the image will update in real time, which may cause a Slight response delay in larger images. Version No. 1.0 159 Date : 14/10/2013

Structural

Custom

Image Metadata

Image width
2481 px
Image height
3508 px
Image resolution
300 px/inch
Original File Size
1.3 MB
Permalink to jpg
srb_000007/0166.jpg
Permalink to ocr
srb_000007/0166.ocr

Privacy

  • Privacy policies
  • Cookies

  • https://facebook.com/tripont

Website

  • heritazs.hu
  • phaseone.hu
  • tripont.hu
  • tripont.hu/problog

Contact

  • +36 30 462 23 40
  • klinger.gabor@tripont.hu
  • 1131 Budapest,
  • Reitter Ferenc utca 132/J.

  • Copyright © 2023 Tripont Kft.
  • Copyright © 2024 Tripont Kft.

Heritázs

LoginRegister

User login

I forgot my password
  • Search
  • Collections
Englishen
  • Magyarhu
  • Српскиsr
  • Serbo-Croatiansh